| ObservationXInfoGUID |
| Definition | A foreign key to the GUID column in the CV3ObservationCUR table. |
| IOSubtype |
| Definition | A dictionary value from either the Intake or Output Subtypes dictionaries, depending on the Fluid Balance selection or the Calculation Type. |
| IncludeInTotals |
| Definition | Indicates if this item should be included in Total Intake/Output calculations by default. 1 = True; 0 = False |
| InValue |
| Definition | Charted value IN of observation |
| OutValue |
| Definition | Charted value OUT of observation |
| DailyValue |
| Definition | The Cumulative 24 hr value |
| BagNumber |
| Definition | Bag number attached |
| BagVolumeUnit |
| Definition | UOM for bag volume |
| BagVolume |
| Definition | Volume of the bag attached |
| InitialBagVolume |
| Definition | Initial volume of the bag |
| BagAttributes |
| Definition | bit mask field for bag attributes related to drips (1-more than one bag within 24hr) |
| ValueRate |
| Definition | The rate as charted in case of drip generic |
| ValueDose |
| Definition | The dose as charted in case of drip generic |
| PatConditionOut |
| Definition | The condition of the patient against the value charted1- Very Low, 2 - Low, 3 - High, 4 - Very High, 5 - Abnormal, 6 - Very Abnormal, 7-Normal. By default is 7. |
| FormattedValueText |
| Definition | Formatted free text observation string |
| MSReplrowguid |
| Definition | Unique GUID used to support merge replication. |
| SmartPumpOrderTaskID |
| Definition | Refers to the SXACDSmartPumpOrderTask.SmartPumpOrderTaskID for which the data has been auto entered. |
| SmartPumpEventInfo |
| Definition | Holds the Smart Pump Event Type. E.g. Infusion Start, Infusion Stop, Rate Changed, Infusion Complete, KVO Start, KVO Stop, Bolus Start, Bolus Stop. |
| DataCapturedAtUTC |
| Definition | Holds the time in UTC at which the actual data was captured for a charted observation. For E.g. For Smart Pump observations, this field will hold the value of the infusion time provided by the Smart Pump, however, this value can be charted on a flowsheet with a different time.selected and charted for a flowsheet time column. |
| FanoutSource |
| Definition | Specifies the source of fanout. It can be Document Name in for SN to FS fanout and Order Name for Task to FS fanout. |
| FanoutSourceType |
| Definition | Specifies the fanout source type. 1 = Flowsheet, 2 = Structured Notes, 3 = Task |
| FanoutSourceUpdReason |
| Definition | Store Observation Update Reason when something was changed on Source. |
| ArcType |
| Definition | A foreign key to the ArcType column in the CV3ObservationCUR table. |